MITSUBISHI ELECTRIC SDP-Eco 1630 III User Manual

Page 50

Advertising
background image

SDP-Eco1630 III USERS MANUAL

Remaining amount of plate

The remaining amount of plate should be set in meter units when you use a
new plate.
The initial setting value is 0 meter.
The remaining amount of plate is shown in 1 meter increments (0 to 75
meters) in the remote mode display
The remaining amount value is calculated by subtracting the exposed plate
length from the plate length set by the operator. The plate length for
preliminary feeding is also subtracted.
However, the accuracy of the remaining length measurement is not
guaranteed. Please regard this value simply as a reference guide.

6.2 Laser menu

The laser menu contains a command to set the laser for exposing the current
plate.

Resolution setting

(12) ......1200dpi
(15) ......1500dpi
(18) ......1800dpi
(24) ......2400dpi

Laser setting

From the panel, you can set the exposure laser for each resolution to be used
with the current plate.
1) Set the resolution and laser value.
2) If necessary, expose a trial sheet to adjust the laser.

- 42 -

Plate type

Resolution Laser value

Sample panel display

F 1 7 5 ( 1 2 ) 2 0 0