Chapter 9 specifications – MITSUBISHI ELECTRIC SDP-Eco 1630 III User Manual
Page 81
Chapter 9 Specifications
Chapter 9 Specifications
9.1 Basic specifications
- Recording system
...
Flatbed scanning system
- Light source
...
635 nm laser diode
- Resolution
...
1200 dpi, 1500 dpi, 1800 dpi, 2400 dpi
- Exposure speed
...
1236 mm/min (1200 dpi)
791 mm/min (1500 dpi)
549 mm/min (1800 dpi)
309 mm/min (2400 dpi)
- Plates
...
SDP-FR100 (Winding length: 75 meters)
SDP-FRm175 (Winding length: 61 meters)
SDP-RR175 (Winding length: 75 meters)
- Plate width [cm (inches)]
...
22.9 (9), 25.4 (10), 27.9 (11), 30.5 (12),
31.0 (12 1/5),32.4 (12 3/4), 33.5 (13 3/16),
34.0 (13 3/8),37.0 (14 9/16), 40.0 (15 3/4),
40.4 (15 7/8),41.4 (16 3/10)
- Effective exposure width
...
404 mm
- Maximum exposure width
...
424 mm
- Plate cut length
...
220 to 580 mm
- Cutter
...
Slide cutter
- Plate joint detector
...
Panel display, automatic over cut
- Dehumidifier
...
Panel heater
- Activation method
...
Coating (Ecology adapted model)
- Tank capacity
...
SLM-EAC 0.55 liters, SLM-EST 0.6 liters
- Processing chemicals
...
SLM-EAC, SLM-EST (2 liters per bottle)
- Rinse water tank
...
0.26 liters
- Rinse water
...
Rinse water replenisher bottle 1.0 liters
- Processor speed
...
15 mm/sec.
- Original speed
...
114 sec. (1200 dpi 450 mm long)
...
189 sec. (2400 dpi 450 mm long)
- Cycle time
...
44 sec. (1200 dpi 450 mm long)
...
124 sec. (2400 dpi 450 mm long)
- Solution temperature control ...
140W (AC 115V) panel heater 30 to 34 ˚C
- Plate preheater
...
140W (AC 115V) heat roller
- Dryer
...
600W (AC 115V) fin heater
Thermo controller switch system (H or L)
- Interface
...
FAST WIDE SCSI (16 bit)
- Power supply capacitance
...
Single phase 100 to 120V, 10A, 1.2 kW, 50/60 Hz
Single phase 200V 6A/ 220V 5.5A/ 230V 5.5A
240V 5A/ 1.2 kW 50/60 Hz
- Machine size (mm)
...
W 1000 x D 795 x H 1070
- Weigh
...
100 to 120V type: 185 kg
200/220/230/240V type: 207 kg
- Installation environment
...
Temperature 18 to 28˚C, Humidity 50 to 70%
- Noise
...
60 dB (A) or lower
- Option
...
Memory module for extension
Differential unit (Cable 20 meters)
DS punch unit (Alternately positionable)
BELL punch unit
- 73 -