4) Attach the supply pipe to the

processing chemical supply hose.

5) Install the processing chemical

supply pipe.

When the processing
chemical supply pipe is
clogged, clean the pipe
regardless of the time
elapsed.

Cleaning the nip roller and exit roller

(upper)

Always clean the rinse water

nip roller and upper exit roller
after processing 1000 plates
or every month.

1) Loosen the set screw (with a

coin) to remove the left processor
rail.

2) Pull out the left processor rail

toward the operator side.

3) Lift up and remove the rinse

water nip roller.

The rinse water nip roller weighs approximately 2 kilograms, so please
be very careful when handling it.

Note

Caution

Chapter 7 Maintenance

- 55 -

Screw section

Hole

Hole

Processor rail (left)

Set screw

Rinse water nip roller

Exit roller (upper)

Caution