6 volume set error, Volume set error -11, Volume set error – Motorola SSETM 5000 User Manual

Page 115

Advertising
background image

6881094C12-A

November 11, 2004

Troubleshooting Charts: Volume Set Error

9-11

9.6

Volume Set Error

MAEPF-27401-B

No

No

No

Yes

Yes

Yes

Volume

Set Error

Using a voltmeter,

measure voltage at

U507 pin 1, when volume

knob is all the way on.

The value should be V2*

Voltage

Functional?

Replace

U501

Verify connections

and control top/PTT

flex connections

Volume

check OK?

Refer to 

VOCON RX

 Audio flowchart

Verify operation

of volume knob

using Button Test

flowchart

Replace

U507

Volume

pot OK?

Replace

Housing

Assembly

This chart relates to a failure in the volume
set knob. Basic failure modes are as follows:
1) Failure in control top/PTT flex circuit
2) Bad connection
3) Defective volume control potentiometer
4) Defective A/D port in GCAP II
5) Problem in receive audio circuit

Synopsis

Measure voltage from

R526 to GND while

moving volume knob

from min to max. Max

volume is 2.50V

* per Standard Bias Table