6881094C12-A

November 11, 2004

Troubleshooting Charts: Button Test

9-13

9.8

Button Test

MAEPF-27399-A

End

Buttons

correct?

Check signal

path integrity of

button in question

Button Test

Place radio in Test Mode.

Press Top Side Button

(Monitor) so display reads

CH TEST. This places the

radio in button test mode.

Then, press the green

(display) button to verify 

codes display as shown

 in the Button Table at right

No

Yes

This chart relates to a failure in the button functions.
Basic Failure modes are as follows:

1) Failure in control top/PTT 
2) Bad Connection
3) Defective Switches or pads
4) Defective A/D port in GCAP II

Synopsis

Button Table

Button
PTT
Volume Control Knob
Display Button
Channel Select (Frequency)
Channel Bank Select
Top Side Button (Monitor)
Two-Dot Side Button
One-Dot Side Button 

Code

1/ 0-1

2/ 0-255

3/ 0-1

4/ 0-15
67/ 0-2
96/ 0-1
97/ 0-1
98/ 0-1