9.16 Secure Hardware Failure

MAEPF-27387-O

Yes

No

Yes

No

No

No

Fail

09/10 or 09/90

Secure Hardware

Failure

Connections

good?

Repair

connections

Yes

Replace

secure

module

Verify electrical activity
at the following signals
at power up:

Connections

good?

Repair

opens

No

Yes

Is

known good

module

available?

Replace module

with known good

one and retest

Verify connections

to secure module

through J701

Signals

good?

Yes

Replace

secure

module

Radio

functions with

known good

module?

Replace

respective

source IC or

VOCON board

This failure relates only to secure-equipped
radios and indicates a power-up self-test failure
for the secure module. More specifically this
failure indicates a failure in communications
between the DSP and secure module. The
secure module is not considered field repairable
so troubleshooting is limited to verifying a
problem with the module and replacing.
Typical failure modes would be:
1) Open between secure module and VOCON
board at J701.
2) Failure of the SSI bus that the DSP uses to
communicate with the secure module.
3) Failure to get proper supplies and grounds
to J701.

Synopsis

Use ohmmeter to electrically
verify the following signal
connections to source IC:

Signal @ J701 Source
ENC_SSI_DI R403
ENC_SSI_DO R402
ENC_SSI_CLK R405
RESET_ENC R418

Verify bias of following signals:
Signal @ J701 Nominal Bias
UNSW_B+ 7.5VDC+/-1.0VDC
SW_B+ 7.5VDC+/-1.0VDC
GND GND

Signal @ J701 Source
ENC_SSI_DI R403
ENC_SSI_CLK R405