Motorola SSETM 5000 User Manual

Page 61

Advertising
background image

6881094C12-A

November 11, 2004

Test Equipment and Service Aids: Service Aids

3-5

ChipMaster Nozzles:

6680333E28

PA nozzle

Soldering and unsoldering ICs

3

6680332E83

PLCC-28* nozzle

6680332E93

PLCC-32 nozzle

6680332E82

PLCC-44* nozzle

6680332E94

PLCC-52 nozzle

6680332E95

PLCC-68* nozzle

6680332E96

PLCC-84 nozzle

6680332E89

QFP-80 nozzle

6680332E90

QFP-100* nozzle

6680332E91

QFP-132* nozzle

6680334E67

QFP-160 nozzle

6680332E86

SOIC-14/SOL-16J
nozzle

6680333E46

SOL-18 nozzle

6680332E84

SOIC-20 nozzle

6680332E87

SOL-20J nozzle

6680333E45

SOL-24 nozzle

6680332E88

SOL-28J nozzle

6680333E54

TSOP-32 nozzle

6680333E55

TSOP-64 nozzle

* Included with ChipMaster packages

To maintain the integrity of the RF PA, never heat it above 210

°

C while performing repair or

rework procedures. To prevent overheating the RF PA during rework, use a ChipMaster (R1319
or R1321) top-side pre-heat set point of 215

°

C and a Dragon (R1427) bottom-side pre-heat set

point of 204

°

C for 1 minute before and throughout top-side heat application, assuming that the

RF PA is removed from the applied heat 10 seconds after reflow occurs. (The RF PA
temperature does not reach the ChipMaster’s internal set point temperature). All other parts on
the transceiver board can be reworked with ChipMaster top-side heat alone.

Table 3-2. Service Aids (Continued)

Motorola

Part

Number

Description

Application

Service

Level

!

C a u t i o n

Advertising