Rx rf—page 3 – Motorola SSETM 5000 User Manual

Page 126

Advertising
background image

November 11, 2004

6881094C12-A

9-22

Troubleshooting Charts: RX RF

RX RF—Page 3

TP502

= 0 Vdc?

No

No

Yes

Yes

Repair

defects

Measure RF levels at first preselector

filter and compute filter loss.

UHF: TP13, U401-3

No

Yes

Loss < 3 db?

Measure RF levels at LNA

and compute LNA gain.

UHF: U401-1, TP402

Measure RF levels at second preselector

filter and compute filter loss.

UHF: TP402, TP403

Gain

about

+12 dB?

2

6

No

Yes

Measure RF and IF level at mixer

and compute mixer conversion gain.

UHF: TP403, TP404

Loss

< 3 dB?

8

No

Yes

Measure

control voltage

at TP502

No

Yes

Fvco

too low?

UHF: < 71.1 MHz

Remove Abacus shield and

inspect second LO VCO.

UHF: SH501

TP502

= 5 Vdc?

3

5

5

No

Yes

Replace

Varactor D550

Check

LNA

Check

mixer

Visual

examination

OK?

No

Yes

Measure IF level at XTAL filter

and compute XTAL filter loss.

UHF: TP404, TP12

Mixer

gain about

4 dB?

No

Yes

No problem

found

Loss

< 3 dB?

7

MAEPF-27472-B

TP502

(Vdc)

TP501

(MHz)

Fvco

1.7
3.7

71.1
75.6

UHF R1