SECTION 4—SAFETY INSPECTION/TROUBLESHOOTING

Part No 1143190

31

TDX™ SP

Troubleshooting - Electrical

NOTE: For additional troubleshooting information and explanation of error codes, refer to the 
individual Electronics Manual supplied with each wheelchair.

SPJ™+, SPJ+ w/PSS or SPJ+ w/ACC Joysticks

The joystick information gauge and the service indicator give indications of the type of 
fault or error detected by the control module. When a fault is detected, the wheelchair 
may stop and not drive. The LEDs on the information gauge may flash in a particular 
pattern or the service indicator light will flash. The number or type of flashes indicates the 
nature of the error. If multiple errors are found, only the first error encountered by the 
control module will be displayed.

Information Gauge Display Diagnostics

DISPLAY

DESCRIPTION

DEFINITION

COMMENTS

All LEDs are off.

Power is off.

All LEDs are on.

Power is on.

Fewer than three LEDs on
implies reduced battery
charge.

Left RED LED is flashing.

Battery charge is low.

The batteries should be
charged as soon as possi-
ble.

Left to Right “chase”
alternating with steady
display.

Joystick is in
programming, inhibit and/
or charging mode.

The steady LEDs indicate
the current state of the
battery charge.

All LEDs are flashing slowly. Joystick has detected Out-

of-Neutral-at-Power-Up
mode.

Release the joystick back
to Neutral.

Information

Gauge

Display

Advertising