SECTION 5—WHEELCHAIR OPERATION

TDX™ SP

44

Part No 1143190

Remote On/Off Switch

The remote On/Off switch input is located at the rear of the joystick on the right side and 
allows the power switch to be operated by an ability switch (normally open momentary 
switch with mono plug). To use the remote On/Off feature, the Drive Select/On/Off switch 
must be in the On position. Each activation of the ability switch will alternately turn the 
joystick On or Off.

Mode Switch

NOTE: For this procedure, refer to FIGURE 5.4 on page 40.

The mode switch is used to select the operating mode for the wheelchair. The mode 
switch is located on the joystick. A mode switch is needed whenever any of the following 
operating modes are programmed:
• Environmental Controls (ECU 1, ECU 2, ECU 3, ECU 4)*
• 3 Speed Mode in Digital 3 Speed (Slow, Medium, Full)
• Latched Modes
• Sleep Mode
• RIM Mode*
• Remote Drive Selection Mode*
• Tilt/Recline Mode*
• Information Center Display Selection (does not require Reset activation at power up)

If any of the above modes are selected, the control will require activation of the switch 
immediately after the power switch is turned On in order to enter the drive mode. The 
second line of the LCD will display ‐ PRESS RESET.
*NOTE: In these modes, Standby Select allows the reset switch to be bypassed for users unable to 
activate the switch.

Memory Card Slot

The memory card slot is used with the basic or professional memory card for saving or 
reading wheelchair parameters. 