Installing sfps – Juniper Networks ERX Hardware 8 User Manual

Page 113

Advertising
background image

Maintaining ERX Routers

CAUTION: For port redundancy to operate correctly, both the primary and
redundant ports on a GE I/O module must use the same type of SFP.

Installing SFPs

To install SFPs:

1.

Put the antistatic wrist strap on your wrist, and connect the strap to the
ESD grounding jack on your system.

2.

Identify the following items on the SFP, as shown in Figure 41:

The connection circuitry on the base

The cable connectors on the front

The cable connectors are protected by a dust cover.

Figure 41: Example of SFP

Cable connectors

on front

Connection circuitry

on base

g013436

CAUTION: Be sure to position the SFP correctly before you install it.

3.

Hold the SFP so that:

The connection circuitry is adjacent to the TX and RX markings on
the module’s faceplate.

The front will be visible when you install the SFP.

For the correct orientation, see Figure 42.

Replacing SFPs on I/O Modules

95