ERX 8.0.x Hardware Guide

CAUTION: If you meet strong resistance when attempting to seat the module using
the ejectors, remove it from the chassis and confirm that the slot is designed to hold
the module. Then verify, if applicable, that the module matches its corresponding
module (I/O module or line module). Also, be sure that you have aligned the top
and bottom edges in the correct matching tracks.

CAUTION: Be sure to cover every empty slot with a blank filler panel to protect the
system from dust or other foreign substances and to ensure proper system cooling.

CAUTION: Do not discard the antistatic bag. When a module is not in use, store it
in an antistatic bag.

Order of Installation

Before you attempt to install or replace a line module (inserted in the front of
the chassis), make sure the corresponding I/O module (inserted in the rear of
the chassis) is already in place. The slot diagnostics run when a line module
is installed in a chassis slot. If the corresponding I/O module is not present, the
diagnostics fail, and you need to remove and reinsert the module.

Required Tools and Safety Items

You need the following tools to install a line module:

A Phillips screwdriver

An ESD wrist strap

Safety Guidelines

Before and during the installation process, observe the following precautions:

WARNING: Do not work on the system or connect or disconnect cables during
lightning activity.