Cabling ERX Routers

Table 9: Power Input Module Cables and Wires Needed

Cable/Wire

From

To

ERX-14xx models

One 10-AWG ground wire

Power input module ground terminal

Termination ground

Two 8-AWG wire leads

Power input module Power A –48 VDC
and RTN leads

Appropriate leads on power source No.1

Two 8-AWG wire leads

Power input module Power B –48 VDC
and RTN leads

Appropriate leads on power source No.2

ERX-7xx models

One 10-AWG ground wire

Power input module ground terminal

Termination ground

Two 12-AWG wire leads

Power input module Power A –48 VDC
and RTN leads

Appropriate leads on power source No.1

Two 12-AWG wire leads

Power input module Power B –48 VDC
and RTN leads

Appropriate leads on power source No.2

ERX-310 router

One 10-AWG ground wire

Power input module ground terminal

Termination ground

Two 14-AWG wire leads (DC model only)

Power input module Power A –48 VDC
and RTN leads

Appropriate leads on power source No.1

Two 14-AWG wire leads (DC model only)

Power input module Power B –48 VDC
and RTN leads

Appropriate leads on power source No.2

One AC power cord (AC model only)

Power input module AC power IEC
receptacle

Appropriate AC power supply

Cabling the Router for Power

61