Juniper Networks ERX Hardware 8 User Manual

Page 61

Advertising
background image

Installing Modules

3.

With a Phillips screwdriver, loosen the captive screws that secure the blank filler
panel covering the empty chassis slot, if present, and remove the filler panel.

4.

Remove the SRP module from its antistatic bag, being careful not to touch
module components, pins, leads, or solder connections.

5.

Verify that the ejectors are in the open position, as shown in Figure 20.

Figure 20: Ejectors in the Open Position

Opened

Œ

Closed



Opened

Œ

Closed



g013746

6.

Slide the module into the chassis by placing it between the guides of the
selected slot and pushing the module until it stops.

The module stops sliding when the ejectors make contact with the front
of the chassis.

CAUTION: If you meet strong resistance when attempting to seat the module using
the ejectors, remove it from the chassis and confirm that the slot is designed to hold
the module. Then verify, if applicable, that the module matches its corresponding

Installing SRP I/O and SRP Modules

43