Juniper Networks ERX Hardware 8 User Manual

Page 65

Advertising
background image

Installing Modules

Figure 21: Ejectors in the Closed Position

Closed



Opened

Œ

Closed



Opened

Œ

g013747

5.

Carefully slide the module out of the chassis.

6.

Place the module in its antistatic bag, being careful not to touch module
components, pins, leads, or solder connections.

7.

Cover the empty chassis slot with a blank filler panel, and tighten the filler
panel’s captive screws using a Phillips screwdriver. Turn both screws several
times before tightening them completely.

If you remove an I/O module and not the corresponding line module, the line module
reboots. Its status becomes inactive when you issue the show version command.

If you remove a line module and do not delete the corresponding
configuration, the status of the line module is listed as not present
when you issue the show version command.

Removing a Line Module, SRP Module, or SRP I/O Module