Samsung S3C2440A User Manual

Page 325

Advertising
background image

S3C2440A RISC MICROPROCESSOR

UART

11-21

UART BAUD RATE DIVISOR REGISTER

There are three UART baud rate divisor registers including UBRDIV0, UBRDIV1 and UBRDIV2 in the UART block.
The value stored in the baud rate divisor register (UBRDIVn), is used to determine the serial Tx/Rx clock rate
(baud rate) as follows:

UBRDIVn

= (int)( UART clock / ( buad rate x 16) ) –1

( UART clock : PCLK, FCLK/n or UEXTCLK )

Where, UBRDIVn should be from 1 to (2

16

-1), but can be set zero only using the UEXTCLK which should be

smaller than PCLK.

For example, if the baud-rate is 115200 bps and UART clock is 40 MHz, UBRDIVn is:

UBRDIVn

= (int)(40000000 / (115200 x 16) ) -1

= (int)(21.7) -1 [round to the nearest whole number]

= 22 -1 = 21

Register Address

R/W

Description

Reset

Value

UBRDIV0

0x50000028

R/W

Baud rate divisior register 0

-

UBRDIV1

0x50004028

R/W

Baud rate divisior register 1

-

UBRDIV2

0x50008028

R/W

Baud rate divisior register 2

-

UBRDIV n

Bit

Description

Initial State

UBRDIV

[15:0]

Baud rate division value UBRDIVn > 0
Using the UEXTCLK as input clock, UBRDIVn can be
set ‘0’.

-