S3C2440A RISC MICROPROCESSOR

ARM INSTRUCTION SET

3-9

DATA PROCESSING

The data processing instruction is only executed if the condition is true. The conditions are defined in Table 3-2.
The instruction encoding is shown in Figure 3-4.

31

24

27

19

15

Cond

Operand2

28

16

11

12

21

[15:12] Destination register

0 = Branch

1 = Branch with link

[19:16] 1st operand register

0 = Branch

1 = Branch with link

[20] Set condition codes

0 = Do not after condition codes

1 = Set condition codes

[24:21] Operation codes

0000 = AND-Rd: = Op1 AND Op2
0001 = EOR-Rd: = Op1 EOR Op2
0010 = SUB-Rd: = Op1-Op2
0011 = RSB-Rd: = Op2-Op1
0100 = ADD-Rd: = Op1+Op2
0101 = ADC-Rd: = Op1+Op2+C
0110 = SBC-Rd: = OP1-Op2+C-1
0111 = RSC-Rd: = Op2-Op1+C-1
1000 = TST-set condition codes on Op1 AND Op2
1001 = TEO-set condition codes on OP1 EOR Op2
1010 = CMP-set condition codes on Op1-Op2
1011 = SMN-set condition codes on Op1+Op2
1100 = ORR-Rd: = Op1 OR Op2
1101 = MOV-Rd: =Op2
1110 = BIC-Rd: = Op1 AND NOT Op2
1111 = MVN-Rd: = NOT Op2

[25] Immediate operand

0 = Operand 2 is a register

1 = Operand 2 is an immediate value

[11:0] Operand 2 type selection

26 25

00

L

20

OpCode

S

Rn

Rd

0

Rotate

Shift

Rm

[3:0] 2nd operand register

[11:4] Shift applied to Rm

3

11

0

4

8

11

0

7

Imm

[7:0] Unsigned 8 bit immediate value

[11:8] Shift applied to Imm

[31:28] Condition field

Figure 3-4. Data Processing Instructions