Configuring snmp trap notification – Symantec Veritas 5 User Manual

Page 73

Advertising
background image

If you do not want to add, answer n.

Would you like to add another SMTP recipient? [y,n,q,b] (n)

5

Verify and confirm the SMTP notification information.

SMTP Address: smtp.example.com

Recipient: [email protected] receives email for Warning or

higher events

Recipient: [email protected] receives email for Error or

higher events

Is this information correct? [y,n,q] (y)

Configuring SNMP trap notification

You can choose to configure VCS to send event notifications to SNMP management
consoles. You need to provide the SNMP management console name to be notified
and message severity levels.

Note that you can also configure the notification after installation.

Refer to the Veritas Cluster Server User's Guide for more information.

To configure the SNMP trap notification

1

Review the required information to configure the SNMP notification feature
of VCS.

2

Specify whether you want to configure the SNMP notification.

Do you want to configure SNMP notification? [y,n,q] (y)

If you skip this option and if you had installed a valid HA/DR license, the
installer presents you with an option to configure this cluster as global cluster.
If you did not install an HA/DR license, the installer proceeds to configure
VCS based on the configuration details you provided.

See

“Configuring global clusters”

on page 74.

3

Provide information to configure SNMP trap notification.

Provide the following information:

Enter the SNMP trap daemon port.

Enter the SNMP trap daemon port: [b,?] (162)

Enter the SNMP console system name.

73

Installing and configuring VCS

Installing and configuring VCS 5.0 RU3