Recommended piping installation – Sierra Monitor Corporation HRG015-W User Manual

Page 36

Advertising
background image

HRX-OM-J049-A
Chapter 3 Transport and Installation

3.2 Installation

HRG010-W HRG015-W

1st edition : Aug. 2006

Rev. A: May. 2007

3-14

„

Recommended piping installation

Table 3-6 Recommended Piping Installation

Size

No.

Name

HRG010-W

HRG015-W

1 Valve Rc1/2 Rc3/4
2 Y-shaped

strainer

Rc1/2

Rc3/4

3

Pressure gauge

0 to 1.0 MPa

4 Valve

Rc3/4

5

Relieving valve

Rc3/4, set from 0 to 0.5 MPa

6 Y-shaped

strainer

Rc3/4

7

Flow meter

Rc3/4, 0 to 100 L/min

[Tips]

Optional accessories listed below are available for the relieving valves shown
in Fig. 3-12 “Recommended Piping Installation”. Separate order for optional
accessories is to be placed upon designing the piping system if used for
piping installation.

Table 3-7 Allied Products

Part No.

Name

Qty.

Note

HRG-BP010

Bypass (relieving valve) piping set

1 set

HRG010 optional accessory

HRG-BP015

Bypass (relieving valve) piping set

1 set

HRG015 optional accessory

Fig. 3-13 Recommended Piping Installation

Load device

To the drain port

Circulating fluid OUT

Circulating fluid RETURN

Tank drain port

Port for overflow

Facility water IN

Facility water OUT

Auto supply port

Fluid supply

Facility water

Advertising