Sanyo R410A User Manual

Page 20

Advertising
background image

20

Fig. 2-5

Fig. 2-6

Fig. 2-7

2-2. Outdoor Unit

AVOID:

● heat sources, exhaust fans, etc.
● damp, humid or uneven locations
● indoors (no-ventilation location)

DO:

● choose a place as cool as possible.
● choose a place that is well ventilated.
● allow enough room around the unit for air intake/

exhaust and possible maintenance.

Installation Space

Install the outdoor unit where there is enough space for ven-

tilation. Otherwise the unit may not operate properly. Fig. 2-6

shows the minimum space requirement around the outdoor

units when 3 sides are open and only 1 side is shuttered,

with open space above the unit. The mounting base should

be concrete or a similar material that allows for adequate

drainage. Make provisions for anchor bolts, platform height,

and other site-specific installation requirements.

CAUTION

Leave space open above the

unit.

Construct louvers or other

openings in the wall, if nec-

essary, to ensure adequate

ventilation.

NOTE

● Do not do any wiring or tubing within 1 ft. of the front

panel, because this space is needed as a servicing

space for the compressor.

● Ensure a base height of 4 in. or more to ensure that

drainage water does not accumulate and freeze

around the bottom of the unit.

● If installing a drain pan, install the drain pan prior to

installing the outdoor unit.

* Make sure there is at least 6 in. between the outdoor

unit and the ground.

Also, the direction of the tubing and electrical wiring

should be from the front of the outdoor unit.

Out-
door
unit

Heat
source

Hot air

Exhaust fan

More than
2 in.

More than
1.7 ft.

* More than 4 in.

* More than 4 in.

* More than 4 in.

Example of installation of 2 units

(When wall height is below 6 ft.)

* However, be sure to ensure a space of 1 ft. or more at

either the right side or the rear of the unit.

35-3/64 (Ceiling panel dimensions)

35-3/64 (Ceiling panel dimensions)

74-1/64 (Ceiling panel dimensions)

31-7/64 (Installation hole pitch)

31-7/64 (Installation hole pitch)

70-5/64 (Installation hole pitch)

7-7/8

3-15/16

Top view

3

5-

3

/64 (Ceili

ng

pa

n

el dime

ns

io

ns

)

3

6-7/

3

2 (I

ns

tallatio

n

hole pitch)

3

7-1

3

/3

2 (Maxim

u

m dime

ns

io

ns

)

Unit: in.