85464359982001(usa eco-i_5) – Sanyo R410A User Manual
Page 56
56
Fig. 4-6
Remove 2 screws
Tubing cover
Bottom
Front
Remove 11 panel
screws from front
panel
Use cutting pliers or similar
tool to cut cover out
Fig. 4-5
Indentation
(4 locations)
Slit hole
4-3. Routing the Tubing
● The tubing can be routed out either from the front or from the bottom. (Fig. 4-6)
● The connecting valve is contained inside the unit. Therefore, remove the front panel. (Fig. 4-6)
(1) If the tubing is routed out from the front, use cutting pliers or a similar tool to cut out the tubing outlet slit (part indicated
by
) from the tubing cover. (Figs. 4-5 and 4-6)
(2) If the tubing is routed out from the bottom, remove the
slit part (
).
● Use a drill bit approximately 13/64 dia. to create holes at
the 4 slit hole indentations (openings).
● Punch out the slit part (
).
● Be careful not to damage the base plate.
07-007 W-2WAY_II_NA 1/23/07 6:09 PM Page 56