Refrigerant tubing joint
(gas tube)

Refrigerant tubing joint
(liquid tube)

Drain pipe connection
(Be sure to connect the
supplied flexible hose.)

Inter-unit Control Wiring

Power supply outlet

35

A

Fig. 3-46

Route the power wiring into the indoor unit through the power inlet on the side of the unit. At this time, be
sure that the wiring passes through the power inlet in the unit power section. If the wiring does not pass
through this inlet, it may become pinched by the ceiling panel, and may result in fire.

Pass the wiring through the power inlet on the electrical component box and connect it to the terminal plate.
Then fasten the wiring in place with the clamp.

WARNING

3-12. Electrical Power Wiring

(1) Wiring connections

The power inlet is on the side of the indoor unit where the
refrigerant tubing is located. The electrical component box
is on the lower air intake surface of the indoor unit.
(Fig. 3-46)

(2) Wiring

3-13. How to Install the Ceiling Panel

For fastening
side panel

Part name

Quantity

Appearance

Part name

Quantity

Appearance

Component Parts

ø11/16

"

Ceiling panel

Screw

M5

× 40

or
5/16"

× 9/16"

Washer-head
screw

1

2

4

4

× 12 or 5/32" × 15/32"

3-13-1. Before Installing the Ceiling Panel

Checking the position of the indoor unit

(1) Check that the dimensions of the ceiling opening are

the following:

28-47/64"

× 23-17/64"

* For details, refer to the installation manual that was

supplied with the indoor unit.

(2) Check that the positions of the ceiling surface and

indoor unit are as shown in Fig. 3-47. If the positions
of the ceiling surface and indoor unit are not correct,
problems such as air leakage, water leakage, and flap
operation trouble may occur.

Do not rest the panel facing downwards, lean up against
a wall, or leave it sitting on top of a protruding object.
Doing so may scratch the panel surface.

Do not apply excessive force to the flap.
(Doing so may damage the flap.)

Indoor unit

Ceiling opening dimension

25/

3

2 – 1 i

n

.

Ceiling surface

Fig. 3-47

Be sure that this distance is within the range of 25/32 – 1 in.
If it is not within this range, malfunction or other problems may result.

Flap

Fig. 3-48