Function Mode and Adjustment

6

101

6. Referring to the setting

procedure for Function mode,
set "F7".

7. To perform the adjustment,

press the Start key.

8. Rotate VR61 on PU2 so that the

reading voltage on the multi-
meter becomes DC21.5±0.2V.

9. Cancel the Function Mode.

10. Check the Projection Lamp

voltage in reader mode is
DC17.0±0.3V.

NOTE

In order to prevent damage of the Projection Lamp be careful of the
following items in adjustment.

Do not exceed the DC21.7V during Projection Lamp voltage
adjustment.

Makes full lighting time in F7 mode of the Projection Lamp into less
than 30 seconds.

6.8.8 F8: Reset the Setting Data

Function mode setting value and job program are reset to the default
value.

1. Sets the function mode “F8”.

2. Press the Mode Memory Key.

3. A display window blinks and setting data is cleared.

PU2