5 condenser lens – Kodak 2400DSV User Manual

Page 47

Advertising
background image

4

Mechanical and Electrical

40

4.1.5 Condenser Lens

Overview

Not only must the amount of light projected onto the Screen or CCD
remain even despite changes in the microfilm or magnification ratio, but
also the light coming from the Projection Lamp must be efficiently
condensed. To accomplish this, the machine is equipped with two
Movable Condenser Lens: one convex and one concave.

Movable Condenser Lenses

The Brightness Shift Lever is moved manually according to the
magnification of the Projection Lens being used so that the Movable
Condenser Lenses are moved to the set position. The set position is color-
coded, TYPE 1 to 3, each defined by a corresponding magnification of the
Projection Lens.

Condenser Mirror

Light from the Projection Lamp after having passed through the Movable
Condenser Lenses strikes this Mirror and is reflected onto the Fresnel
Lens.

Fresnel Lens

The Fresnel Lens, which is an acrylic plate with stepped setbacks,
ensures even illuminance from the Lamp.

TYPE

Lens Magnification

Color Code

TYPE1

7.5X

Blue

TYPE1

9X-16X

Blue

TYPE2

13X-27X

Green

TYPE3

23X-50X

Yellow

Fresnel Lens

Condenser Mirror

Projection

Lamp

Brightness
Shift Lever

Movable Condenser

Lenses

Advertising