6 electrical components check, 1 la1: projection lamp, 2 m3: power unit cooling fan motor – Kodak 2400DSV User Manual

Page 121: 3 m4: projection lamp cooling fan motor, 4 pc1: image leading edge sensor, 5 pc2: scan mirror position sensor

Advertising
background image

7

Troubleshooting

114

7.6

Electrical Components Check

7.6.1

LA1: Projection Lamp

7.6.2

M3: Power Unit Cooling Fan Motor

7.6.3

M4: Projection Lamp Cooling Fan Motor

7.6.4

PC1: Image Leading Edge Sensor

7.6.5

PC2: Scan Mirror Position Sensor

1

Is the circuit across both terminals of the
Lamp conducting when the Lamp is removed
from the machine?

→No

Replace LA1.

→Yes

OK

1

Does the Motor start rotating when the Power
ON/OFF Switch is turned ON?

→Yes

OK

↓ No

2

Is the voltage across CN10-1 and GND
DC24V with the Power Switch in the ON
position?

→No

Check wiring.

→Yes

Replace M3.

1

Does the Motor start rotating when the Power
ON/OFF Switch is turned ON?

→Yes

OK

↓ No

2

Is the voltage across CN18-1 and GND
DC24V with the Power ON/OFF Switch in the
ON position?

→No

Check wiring.

→Yes

Replace M4.

1

Is the voltage across PJ8-A3 on PWB-BB
and GND 0V when the Power Switch is in the
ON position and the light emitted by the
Sensor LED is blocked?

→No

Replace PC1.

↓ Yes

2

Is the voltage across PJ8-A3 on PWB-BB
and GND DC5V when the light emitted by the
Sensor LED strikes the Sensor
photosensitive element?

→No

Replace PC1.

→Yes

OK

1

Is the voltage across PJ8-B15 on PWB-BB
and GND 0V when the Power Switch is in the
ON position and the light emitted by the
Sensor LED is blocked?

→No

Replace PC2.

↓ Yes

2

Is the voltage across PJ8-B15 on PWB-BB
and GND DC5V when the light emitted by the
Sensor LED strikes the Sensor
photosensitive element?

→No

Replace PC2.

→Yes

OK