Troubleshooting

110

7.4

Troubleshooting for malfunction code

7.4.1

L2: Projection Lamp malfunction

7.4.2

C1: Scan Unit Drive Malfunction

7.4.3

C2: Scan Mirror Drive malfunction

Check Item

Remedy

Check LA1.

→NG

Replace LA1.

↓OK

The carrier glass is covered by a dark
colored piece of paper or some other
thing that would prevent light from
shining through the glass.

→Yes

Remove paper or any other obstruction
from the carrier glass.

→No

Replace PWB-A.
Replace PWB-BB.

Check Item

Remedy

Does the Scan Table Drive Motor
rotate when the Power Switch is turned
ON?

→No

Wiring Check
Replace the following parts.
PWB-T
PWB-BB
M2

↓Yes

Is C1 shown when scanning motion?

→No

OK

↓Yes

Check PC3.

→NG

Replace PC3.

↓OK

Check PC4.

→NG

Replace PC4.

→OK

Replace PWB-BB.

Check Item

Remedy

Is C2 shown even when power is
turned OFF, then ON again?

→No

OK

↓Yes

Does the Scan Motor rotate when the
Power Switch is turned ON?

→Yes

Check Wiring.
Replace the following parts.
PWB-T
PWB-BB
M1

↓No

Check PC1.

→NG

Replace PC1.

↓OK

Check PC2.

→NG

Replace PC2.

→OK

Replace PWB-BB.