Function Mode and Adjustment

88

6.5.11 Sb: Scan Table Stop Position Adjustment (Scan Position)

This adjustment is necessary when any of the following symptoms occurs.

* The stop position of the Scan Table should be set toward the rear for
symptom 1 explained above and toward the screen for symptom 2.

6.5.12 SC: Scan Table Stop Position Adjustment (Reader Position)

This adjustment is necessary when any of the following symptoms occurs.

* The stop position of the Scan Table should be set toward the screen for
symptom 1 explained above and toward the rear for symptom 2.

Symptom 1.

Each time a print is made, the image on the Screen shifts vertically.

Symptom 2.

The noise becomes big that is heard when the Scan Table hits against
the Scan Table Stopper during its motion from the reader position to
printer position.

Display

setting

Scan Table Stop Position

Sb

d0
|
d8
|
dF

toward the rear
|
center
|
toward the screen

Rear

Screen

Symptom 1.

Each time a print is made, the image on the Screen shifts vertically.

Symptom 2.

The noise becomes big that is heard when the Scan Table hits against
the Scan Table Stopper during its motion from the reader position to
printer position.

Display

setting

Scan Table Stop Position

SC

d0
|
d8
|
dF

toward the screen
|
center
|
toward the rear

Rear

Screen