Roof attachment installation – Lochinvar TISUN SCH-I-O User Manual

Page 17

Advertising
background image

SCH Collectors Installation & Operation Manual

17

SCH Collectors Installation & Operation Manual

3

Roof Attachment Installation

(continued)

Install flat tile hook

1. Determine roof type. Inspect the structural integrity of

the roof and the durability of the roof materials.

2. Determine the number of collectors needed for the

installation and the number of required roof attachments

from Table 3B or 3C on page 11.

3. Determine collector connection points (spacing).

Measure the spacing of the rafters or trusses to confirm

the dimensions and prepare for the system layout

(reference the Roof Attachment Spacing Section on

page

12).

4. Number two (2) tiles, one above the other. The top tile

will be removed to install the flat tile hook.

5. Remove the top tile from the roof (set aside for
reassembly).

6. Place the tiled roof hook over the roof batten of

the bottom tile (FIG. 3-11).

7. Place the metal sheet provided in the kit under the flat

tile hook (FIG. 3-11). Using the nails provided in the kit,

secure the metal sheet to the roof substructure (FIG.

3-11).

8. Secure the tiled roof hook to the roof substructure using

the screws provided in the kit (FIG. 3-11).

9. Replace the tile removed in Step 5.

Note: It may be necessary to grind the top tile to assure a
better fit (FIG. 3-12).

Figure 3-11 Install Flat Tile Hook and Metal Sheet

HOOK FLAT TILE HOOK

ONTO ROOF BATTEN

USE THE NAILS AND

WOOD SCREW

TO SECURE

THE METAL

SHEET AND

FLAT TILE HOOK

TO ROOF

SUBSTRUCTURE

NAIL

NAIL

WOOD

SCREW

PLACE METAL SHEET

UNDER FLAT TILE HOOK

Figure 3-12 Grind Tile(s) (if necessary) / Install Hex Bolt

COLLECTOR

SUBSTRUCTURE

HEX BOLT

SQUARE DISK

IF NECESSARY, GRIND

THE TILE(S) FOR A BETTER

FIT

FLAT TILE

HOOK

10. Slide the square disk onto the hex bolt (see FIG. 3-12).

11. Install the hex bolt with square disk attached into the

opening of the flat tile hook as shown in FIG. 3-12.

Note: Do not tighten hex bolt until ready to install on the
collector substructure.

12. Thread the hex nut (M8) and washer (M8) onto the bottom

of the hex bolt installed in Step 11.

13. Repeat Steps 4 - 12 until installation is complete.

Install hex bolt onto collector substructure (reference Section 4 -
Collector Installation)

Advertising