Collector installation – Lochinvar TISUN SCH-I-O User Manual

Page 31

Advertising
background image

SCH Collectors Installation & Operation Manual

31

4

Collector Installation

(continued)

13. Remove the collector railing and install the Mechanical

Connection Kit (FIG.’s 4-13 and 4-14). Note: Be sure to

bend the tabs down on the Mechanical Connection Kit.

Figure 4-13 Remove Collector Railing

REMOVE COLLECTOR RAILING

Figure 4-14 Install Mechanical Connection Kit

BEND TABS DOWN

14. Reinstall the collector railing removed in Step 13
(FIG.

4-15).

Figure 4-15 Reinstall Collector Railing

REINSTALL COLLECTOR RAILING

OPTIONAL MECHANICAL

CONNECTION KIT

15. Install the side by side bracket using the square disks and

hex bolts provided in the kit (FIG. 4-16).

Figure 4-16 Install Side by Side Bracket

INSTALL SIDE BY SIDE BRACKET

16. Install the plug, sensor well and hydraulic connections to

complete the installation (see FIG.’s 4-17, 4-18 and

4-19).

Figure 4-17 Install Plug

Figure 4-18 Install Sensor Well

Figure 4-19 Install Hydraulic Connections

SENSOR

WELL

EXPANSION

SET (HYDRAULIC

CONNECTION)

PLUG

EXPANSION

SET (HYDRAULIC

CONNECTION)

SCH Collectors Installation & Operation Manual

The Mechanical Connection Kit is an
optional kit available through the
manufacturer.

NOTICE