Introduction, How it works – Lochinvar TISUN SCH-I-O User Manual

Page 4

Advertising
background image

SCH Collectors Installation & Operation Manual

4

SCH Collector

7

1

7

2

4

8

6

3

5

6. Inlet

connection

Copper pipes, .86" diameter.

7. Outlet

connection

Copper pipes, .86" diameter.

8. Absorber

coils

10 mm copper, serpentine arrangement.

9. Hydraulic

connection

kit

Connection set with stainless steel corrugated pipe. For connecting

the collector supply and return to the riser. The corrugated pipes

are available in kits with 2 x 6'-7" or 2 x 13'1" length including

sensor well and plug.

10. Sensor well

For measuring the collector outlet temperature directly in

the fluid. The sensor well can be installed on the outlet connection

as shown on the collector label. The sensor must be inserted up to

the end of the sensor well.

11. Plug

This plug is used on the end collector of each array to complete the

water flow path.

How it works...

1. Housing

Powder coated (RAL7016)aluminum frame structure with

PU rigid foam and an aluminum rear wall.

2. Cover

Prismatic solar safety glass, .15" thick, for maximum light

transmission.

3. Insulation

.76" heat resistant, special PU rigid foam and 1.57" mineral

wool with high pressure resistance, emission free, non-

flammable.

4. Absorber

Full surface absorber, laser welded with highly-selective PVD

coating (PVD = Physical Vapor Deposition), serpentine flow.

5. Collector

seal

Aluminum profile system with double temperature and UV-

resistant silicone seals, emission free.

1

Introduction

10

9

11

Advertising