3

Roof Attachment Installation

(continued)

Figure 3-27 Drill Holes and Attach Flange Plate

COLLECTOR

SUBSTRUCTURE

HEX BOLT

SQUARE DISK

USE THE SMALLER SCREWS

IN THE PERIMETER OF THE

FLANGE PLATE

PRE-DRILL FOUR (4) 6 MM

HOLES - USE THE LARGER

SCREWS TO SECURE THE

FLANGE PLATE

8. Slide the square disk onto the hex bolt (see FIG. 3-27).

9. Install the hex bolt with square disk attached into the

opening of the flange plate as shown in FIG. 3-27.

Note: Do not tighten hex bolt until ready to install on the
collector substructure.

10. Thread the hex nut (M8) and washer (M8) onto the bottom

of the hex bolt installed in Step 9.

11. Repeat Steps 4 - 10 until installation is complete.

Install hex bolt onto collector substructure (reference Section 4 -
Collector Installation)

Corrugated metal roof attachment

#SRM20013

The corrugated metal roof attachment is used for parallel
and inclined mounting on profiled or corrugated sheet metal
roofs. The console is mounted above the mounting screws
of the profiled or corrugated sheet metal. The two sealing
screws are first screwed onto the underlying mounting
screw of the sheet. The sealing is done before the console is
mounted using the sealing pads supplied. The sections are
fixed to the section connectors on the console.

The console must be ordered to

fit the relevant profiled or

corrugated sheet metal.

• The mounting screws supplied
with the console must be

appropriate in type and length for

the particular roof construction.

ƽ CAUTION

Figure 3-29 Kit #SRM20013 - Corrugated Metal Roof
Attachment Kit Components

HEX NUT (M10) (1X)

STUD (M10) (1X)

PROFILE CONNECTOR (1X)

HEX BOLT (M8) (1X)

WASHER (M10) (2X)

HEX NUT (M10) (2X)

WASHER (M8) (1X)

Unpacking and checking parts

When unpacking the system, check the model names of the
components of each system and check to be sure you have the
correct number of parts (see FIG. 3-29).

SCH Collectors Installation & Operation Manual

Figure 3-28 Cover Flange Plate with Roofing Material

COVER FLANGE PLATE WITH

ROOFING MATERIAL, SEALING

IT TO THE ROOF

2”

4.7 mm

4.7”

6”

> 4.7”

Advertising