Collector installation, Ƽ warning – Lochinvar TISUN SCH-I-O User Manual

Page 33

Advertising
background image

SCH Collectors Installation & Operation Manual

4

Collector Installation

(continued)

10. Position the collector onto the substructure (FIG. 4-26).

Figure 4-26 Position Collector On Substructure

ENSURE .2”

OVERHANG

POSITION COLLECTOR

ONTO SUBSTRUCTURE

11. Connect the collector to the bottom end brace using the

square disk and bolt provided in the kit (FIG. 4-27). Do

not

tighten.

12. Position the collector on the U-channels so that the

collector overhangs approximately 5 mm (.2") (FIG.

4-26). Tighten square disk.

13. Install the top end brace using the bolt provided in the

kit (FIG. 4-28).

14. Connect the collector to the end brace using the

square disk and bolt provided in the kit (FIG. 4-28).

15. Ensure all bolts are tightened.

Figure 4-28 Install Top End Brace

CONNECT COLLECTOR TO END BRACE

33

SCH Collectors Installation & Operation Manual

Figure 4-25 Lifting Rings

< 30°

6.5 ft.

< 30°

6.5 ft.

< 30°

6.5 ft.

< 30°

8.5 ft.

9. Ensure lifting rings are installed and spaced properly per
FIG.

4-25.

Figure 4-27 Connect Collector to Bottom End Brace

CONNECT COLLECTOR

TO BOTTOM END BRACE

HEX BOLT

SQUARE DISK

16. For side by side installations repeat Steps 1 - 15 and

install horizontal hydraulic connections (see FIG. 4-29).

Figure 4-29 Install Horizontal Hydraulic Connections

The Mechanical Connection Kit is an
optional kit available through the
manufacturer.

NOTICE

Only loosen the crane connection when
the collectors are completely fixed to the
substructure.

ƽ WARNING

Advertising