SCH Collectors Installation & Operation Manual

Installer – Read all instructions, including
this manual before installing. Perform
steps in the order given.

Have your collector(s) serviced/inspected
by a qualified service technician, at least
annually.

Failure to comply with the above could
result in severe personal injury, death or
substantial property damage.

When calling or writing about the collector
– Please have the collector model and
serial number.

Any claims for damage or shortage in
shipment must be filed immediately
against the transportation company by the
consignee.

Factory warranty (shipped with the
collector) does not apply to collectors
improperly installed or improperly
operated.

ƽ WARNING

NOTICE

1

Introduction

(continued)

Before getting started on your installation be sure to carefully
read the preparation instructions in this section.

• You must comply with local

regulations, laws and standards of the

local governing authority.

• The frame must be capable of

withstanding the local snow and wind

loads and permit the correct
anchoring of the collectors in

accordance with all applicable local

regulations.

• The load bearing capacity of the

roofing and the frame shall be specially

checked or analyzed by a structural

engineer.

• The number of mounting brackets

specified by the Lochinvar/TiSun

manuals and parts sheets is based on

an average collector load bearing per

square foot. The maximum
permissible collector loading per

square foot may be calculated from the

number of mounting brackets, taking

into consideration the permissible

loading on the mounting brackets. If a

higher collector wind and snow loading

(including snow sliding off the roof)

per square foot is required, additional

mounting brackets will have to be

used. Roof pitches in excess of 30° also

represent increased loading; additional

mounting brackets must also be used

for this variant.

ƽ

CAUTION

ƽ

CAUTION

SCH Collectors Installation & Operation Manual

5

Lochinvar/TiSun Solar Thermal Collectors
are not specifically designed for drain back
installations. Consult the factory if drain
back utilization is necessary.

ƽ

CAUTION

• The mounting substructure must be

capable of withstanding the local

snow and wind loads and permit

correct anchoring of the collectors.

• To avoid damage to the collectors

and mounting frames from snow

sliding off the roof, additional snow

guards must be placed in sufficient

numbers around the collectors and

above the collectors.

The collectors must be linked with a

lightning arrester system and/or the

building’s ground system by a licensed

electrician.

Hydraulic connection of the collectors

must be performed according to

Lochinvar/TiSun

specifications.

The collector connections must not be

damaged, soiled or misaligned. Take care

during transport, installation, and

connection of the modules. Do not

remove the header protection caps at the

top and bottom connections of the

collector until just before installation.

When connecting the modules to the

riser, the Hydraulic Connection Kit

(corrugated pipe) supplied must be

installed. Otherwise, the warranty is

invalidated.

Always connect the collector outlet and

inlet flow to each other diagonally,

please follow the connection

example (see FIG. 1-1 on page 6).

Do not twist the headers when screwing

the connections together. Hold threaded

connection in the desired position and

tighten clamping ring union nut to

torque.

Roof penetrations for solar piping must

be adequately sealed against water ingress.

• Use only the original sensor well
supplied.

Use only high temperature and glycol

pipe sealing materials.

All piping should be properly insulated to
avoid freezing and/or burn potential.

ƽ

CAUTION