3

Roof Attachment Installation

Flange plate shingle (raised)

#SRM20008

The raised flange shingle plate is used for inclined installations
on asphalt and elastomer roofs; also suitable for flat roofs.

The plates must be screwed into a

member capable of bearing the

required static load (generally

rafters or concrete).

• Once installed, the panels

must be sealed to the roof sheet

material (FIG. 3-28), and

only then can the collector be

fitted.

ƽ CAUTION

Figure 3-25 Kit #SRM20008 - Flange Plate (Raised) Kit
Components

FLANGE PLATE RAISED (1X)

SCREW (M6) (4X)

HEX NUT (M8) (1X)

WASHER (M8) (1X)

HEX BOLT (M8) (1X)

SQUARE DISK (1X)

SCREW (M10) (4X)

Unpacking and checking parts

When unpacking the system, check the model names of the
components of each system and check to be sure you have the
correct number of parts (see FIG. 3-25).

Install flange plate shingle (raised)

1. Determine roof type. Inspect the structural integrity of

the roof and the durability of the roof materials.

2. Determine the number of collectors needed for the

installation and the number of required attachments

from Table 3B or 3C on page 11.

3. Determine collector connection points (spacing).

Measure the spacing of the rafters or trusses to confirm

the dimensions and prepare for the system layout

(reference the Roof Attachment Spacing Section on

page

12).

4. Caulk (field supplied) around the perimeter of the flange

plate (FIG. 3-26).

5. Using the flange plate as a template, place the flange plate

on the roof and drill four (4) 6 mm holes as shown in

FIG. 3-27. Install the larger screws provided in the kit

into the 6mm holes securing the flange plate to the roof

(caulk around screws before tightening).

6. Install the four (4) remaining smaller screws in the

perimeter of the flange plate as shown in FIG. 3-27 (caulk

around screws before tightening).

7. Cover the flange plate with roofing material, sealing it to

the roof (FIG. 3-28).

Figure 3-26 Caulk Around Perimeter of Flange Plate

CAULK AROUND

THE PERIMETER

OF THE FLANGE PLATE

~ Ø 5 mm

SCH Collectors Installation & Operation Manual