SCH Collectors Installation & Operation Manual

SCH Collectors Installation & Operation Manual

Flange plate shingle (standard)

#SRM20007

The standard flange shingle plate is used for parallel and inclined
installations on asphalt and elastomer roofs.

3

Roof Attachment Installation

4. Choose a cable orientation to ensure proper degree of

angle (see FIG. 3-18).

5. Install the steel cable on the A-frame bracket using the

pin and pin clip provided in the kit (see FIG. 3-19).

6. Attach the steel cable to the joint clamp (fashioned after

the cable orientations in FIG. 3-18.

Figure 3-19 Install Steel Cable on A-frame

INSTALL CABLE

(TURNBUCKLE)

CABLE (TURNBUCKLE)

INSTALLED

INSERT PIN

USE PIN CLIP TO SECURE

THE CABLE

Extend turnbuckle to its fullest extent.

NOTICE

7. Before tightening the joint clamp, set the angle of the

cable to greater than or equal to 30°, but less than or

equal to 45° (see FIG. 3-20).

8. Tighten the joint clamp.

9. Use the turnbuckle to tighten the cable.

Figure 3-20 Cable Angle

Figure 3-18 Cable Orientations

The plates must be screwed into a

support capable bearing the

required load (generally rafters or

concrete).

Once installed, the plates must be

sealed to the roof sheet material

(see FIG. 3-24), and only then can the

collector be fitted.

ƽ CAUTION

Figure 3-21 Kit #SRM20007 - Flange Shingle Plate
(Standard) Kit Components

PLATE FLANGE (STD) (1X)

SCREW (M6) (4X)

HEX NUT (M8) (1X)

WASHER (M8) (1X)

HEX BOLT (M8) (1X)

SQUARE DISK (1X)

SCREW (M10) (4X)

Unpacking and checking parts

When unpacking the system, check the model names of the
components of each system and check to be sure you have the
correct number of parts (see FIG. 3-21).

20