background image

123

ADJUSTMENTS

Note 1 :

The ABL command is valid only in the ABL combination ON (CBY) state.
The ABL level setting and the ABL voltage for the individual units are displayed on the on-screen
display.

Note 2 :

The UP/DOWN commands that can be used for the point convergence adjustment are as follow.

Move up

= UP1

Move down

= DW1

Move to right

= RI1

Move to left

= LE1

Adjustment of each area use the commands as follow.

File area adjustment

RI1 and LE1 are available.

Command name : RP

&, GP &, BP & ( & ; 2, 4, 6, 8, 0)

Line area adjustment

UP1 and DW1 are available.

Command name : RP

&, GP &, BP & ( & ; 1, 3, 5, 7, 9)

Note 3 :

The COL, CON, and COF commands are not valid during RGB input.

Note 4 :

The TV SYSTEM selection command and convergence adjustment data memory area selection com-
mand can be set separately for when the input function is set to VIDEO or Y/C and when it is set to
RGB.

Note 5 :

The TNT commands are not valid during RGB input. Neither valid during PAL input besides RGB.

Note6 :

The SHP commands are not valid during RGB input.

Note 7 :

Turns the combination on/off relay (RY1000) on and off.
The ABL voltage for that individual set can be found by reading the ABL control voltage with the RYN
status. (Refer to GVO: page 126.)
The ABL voltage for the entire connected cube system (the cube with the lowest voltage in the sys-
tem) can be found by reading the ABL control voltage with the RYY status. (Refer to GVO: page 126.)

<Meanings of the command table>
• Normal valid

Command which can be used only when the adjustment mode is set using a command.
√; Receive a command regardless of AJY/AJN
X; Receive a command AJY

• Number direct

Command which can directly be specified as the adjusting value when added with 000 to 255.
√ ; The value provided is a direct command. (Example : For CNT070, the contrast is set to 70.)
X ; Not a Numeral direct command. (Example : For IN1128, only IN1 is executed.)

• UP/DW command

A command which manipulates the adjustment value for the value UPn/ DWn (n is an arbitrary num-
ber between 0 to 9 and F) provided after the command.

Advertising
This manual is related to the following products: