Dip switch setting, Alarm output setting, Dummy black image setting – Panasonic WJ-FS616C User Manual

Page 14

Advertising
background image

14

C If another alarm is received before the existing alarm is

reset, the alarm output lasts as long as the duration set
for the succeeding alarm.

• The O.C position of SW3, SW4, and SW5 corresponds

to their 0/5 V position as shown in the table.

Dummy Black Image Setting

According to the factory default setting, the Dummy
Black Image signal is supplied to the REC OUT con-
nector as needed to overwrite any image displayed by
error. If this function is not required, set the switch SW
1 to the position shown below.

1. Disassemble the video multiplexer as described for

installing the Data Multiplex Boards on page 12

.

2. Set switch (SW1) on the board to the position shown in

the figure.

DIP Switch Setting

Alarm Output Setting

The following settings let you set the polarities of alarm out-
put, alarm reset output, and alarm & SW output on the
ALARM/REMOTE port.

1. Disassemble the video multiplexer as described for

installing the Data Multiplex Boards on page 12.

2. Set switches (SW3/SW4/SW5) on the board to the

required position either Open Collector (O.C) or Pulse
(0/5V) for alarm control signals.

Open Collector (O.C): 16V DC 100 mA max.
Pulse (0/5V): +5V DC approx. 500 ms

The positions in the figure are the factory default setting.

• Timing Table of the signals (0/5 V settings)

0/5V

O.C

SW5

0/5V

0/5V

SW3

O.C

SW4

O.C

SW3 : Alarm Output

SW4 : Alarm Reset Output

SW5 : Alarm & SW Output

0V

Hi-Z

Hi-Z

Hi-Z

100 ms or more

Approx 100 ms

Approx.
450 ms

Alarm output time

0V

Alarm output time

C

Hi-Z

Hi-Z

0V

100 ms or more

Retrigger

5V

Alarm output
(Pin #9)

Alarm input 1

Alarm input 2

0V

5V

Alarm reset
output (Pin #27) 0V

5V

Alarm & SW
Output (Pin #25) 0V

SW1

OFF

SW1 : Record Output

O.C position

0/5 V position

Terminal condition

SW

OFF

Hi-Z

0 V

ON

0 V

5 V