m=0

Quad

m=1

7 divide

m=2

9 divide

m=3

10 divide

m=4

13 divide m=5

16 divide

m=1

No. of divisions (+) m=D No. of divisions (

)

Item

Item

m=0

Manual Reset

m=1

Auto Reset

mm=00 - 16 Camera Number
*00=Spot Input

mm=01 - 16 Playback CH number

Alarm Input

Response

Command (ASCII)

Command Table

(1) Operation Control

Transmission

Command (ASCII)

Parameter (ASCII)

Monitor Select

OMS : m

OMS

m=0

Spot Monitor

m=1

Multiscreen Monitor

m=2

Multiscreen 2 Monitor

VCR/Camera Select

OVC : m

OVC

m=0

Camera Mode

m=1

VCR Mode

Still ON/OFF

OST : m : nn

OST

m=0

Still OFF

m=1

Still ON

nn=00 All video channels specify
nn=01 - 16 Camera Number

Multiscreen Select

OTC : m

OTC

Sequence

OSQ : m

OSQ

m=0

End Sequence

m=1

Activate Sequence

Electronic Zoom
ON/OFF

OZM : m

OZM

m=0

Zoom OFF

m=1

Zoom ON

Single Spot CH Select

OCS : mm

OCS

Camera & Playback Display
Playback CH Select

OVS : mm

OVS

Alarm Reset

OAL : m

OAL

Alarm Log Clear

OAR

OAR

None

Sequence Mode
Select

OSE : m

OSE

m=0

SEQ1

m=1

SEQ2

m=2

SEQ3

OAI : m

OAI

m=0

1CH Alarm

:

m=F

16CH Alarm

(2) Mode Change

Alarm Suspension

MAD : m

MAD

m=0

Alarm Suspension OFF

m=1

Alarm Suspension ON

Lock *1

MKL : m

MKL

m=0

Lock OFF

m=1

Lock ON

Setup

MSU : m

MSU

m=0

End Setup

m=1

Begin Setup

Response

Command (ASCII)

Transmission

Command (ASCII)

Parameter (ASCII)

Note:

If a command has no parameter value, it is processed with the value under lined in the table.

*1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System

Controllers. After execution of this command, only the personal computer can operate the system.