Connections

In this type of installation, only one video multiplexer is con-
nected directly to the system controller by a control cable.
The rest of the video multiplexers are connected to the sys-
tem controller in a daisy-chain type connection.
Refer to the connections and data port settings shown
below.

Notes:

• Up to four video multiplexers can be daisy-chained

to the system controller.

• Unit numbers should be assigned in the order of

connection, starting with the unit connected directly
to the WV-CU550C system controller.

• Sequence display is limited to the cameras con-

nected to one multiplexer unit only.

• It is recommended to set the LOCK switch to the

ON position while making these connections.

• For controlling more than 4 cameras, additional WV-

BP6164 Data Multiplex Boards need to be installed
in the video multiplexer.

Operating Procedure

To control the system, follow the procedure shown below.

1. Confirm that the camera and peripherals are connected

correctly and firmly.

2. Turn on the power switches of all system components.

3. Confirm that the DAISY MODE parameter in the SYS-

TEM SETUP menu is set to ON.

4. Select the unit number of the video multiplexer with the

Numeric key, then press the [MON(UNIT/ESC)] key to
activate the selected unit.

For example, press the keys shown below.

In this example, the image of camera 15 connected to
the video multiplexer Unit 2 is displayed on the Spot
Monitor connected to the video multiplexer Unit 1.

5. Operate the selected unit as described in the OPERAT-

ING PROCEDURES.

6. Select another unit with the Numeric key, then press the

[MON(UNIT/ESC)] key to activate the selected unit.

Other Applications

Application 1

The video signal looped through the SPOT IN connector
can be displayed on the Spot Monitor.

1. Confirm that the DAISY MODE in the SYSTEM SETUP

menu is set to OFF.

2. Select the unit number of the video multiplexer with the

Numeric key, then press the [MON(UNIT/ESC)] key to
activate the selected unit.

3. Press the [F2] button on the controller to select the spot

monitor.

4. Press [ 0 ] then press the [CAM(SET)] key to display the

video looped through the SPOT IN connector on the
Spot Monitor.

TEAM.

OFF

IN

OUT

ON

DATA

SPOT

OUT

I N

TEAM.

OFF

IN

OUT

ON

DATA

SPOT

OUT

I N

IN

OUT

TERM

ON

OFF

DATA

0 1

2

3

45

6

7

8

9

CONTROLLER

UNIT NO.

1-8

Local Site

Main Site

Video Multiplexer

WJ-FS616C

Video Multiplexer

WJ-FS616C

1

2

3

4

5

6

7

8

9

MON

CAM

UNIT/ESC

SET

0

MON

CAM

UNIT/ESC

2

SET

1

5

Unit

2

VIDEO

Unit

1

VIDEO