Quick calibration – PLUS Vision M-5 User Manual

Page 34

Advertising
background image

34

Quick Calibration

The procedure described below is used to adjust (calibrate) for optimum scanning condition of the sheet surface.
Perform this quick calibration procedure after replacing the fluorescent lamp or if dark lines appear in the horizontal
direction when the copyboard is mounted on the wall.

Approx. 10cm

Clean the sheet surface.

First clean a strip about 10 cm wide along the
left side of the sheet surface.
Make sure the sheet is completely clean and there
are no marker traces left.
* Apply some water to a soft cloth, wring out

thoroughly, then wipe the sheet clean. For
tough dirt, wipe using a clean cloth with a so-
lution of diluted neutral detergent, then wipe
again with a cloth dampened with water to re-
move all traces of the detergent.

Caution:
Move the sheet so that the seam of the sheet
does not enter the 10 cm portion at the left side
which is going to be cleaned.

FEED

/STOP

Start the calibration procedure.

Preparations: If the power cord is plugged into a power
outlet, unplug it.

Plug the power cord into a power outlet while
pressing the FEED/STOP button.
• The sheet automatically moves about one brock

of ruled line and calibration is performed.

• The MEMORY indicator blinks slowly during this

process (calibration takes about 5 minutes).

• The power turns off once calibration is completed.

All copyboard operations can be made after turn-
ing on the power.