System, Chapter 9, 165 guitar to midi chapter 9 parameter guide – Roland VG-99 User Manual

Page 165

Advertising
background image

165

GUITAR TO MIDI Chapter 9 Parameter Guide

Chapter 9

SYSTEM

These parameters are applied to the entire VG-99 in the GUITAR TO
MIDI function.

Parameter/
Range

Explanation

CC (Control Change)

You can output the actions of the controllers specified with SRC as
Control Change messages.
You can make two types of settings, 1 and 2.

SRC (Source)

GK VOL

GK-3 GK volume knob

GK S1

GK-3 DOWN/S1 switch

GK S2

GK-3 UP/S2 switch

CTL1

Control button1

CTL2

Control button2

EXP PEDAL

Expression pedal connected to the EXP
PEDAL jack

CTL3

Footswitch connected to the CTL3,4 jack
(jack tip)

CTL4

Footswitch connected to the CTL3,4 jack
(jack ring)

D BEAM V

D BEAM vertical movements

D BEAM H

D BEAM horizontal movements

RIBBON ACT

RIBBON CONTROLLER touch

RIBBON POS

RIBBON CONTROLLER position

FC-300 EXP1

FC-300 expression pedal1

FC-300 EXPSW1

FC-300 expression pedal switch1

FC-300 EXP2

FC-300 expression pedal2

FC-300 EXPSW2

FC-300 expression pedal switch2

FC-300 CTL1

FC-300 control pedal1

FC-300 CTL2

FC-300 control pedal2

FC-300 E3/C3

FC-300 external expression pedal3/external
footswitch3

FC-300 CTL4

FC-300 external footswitch4

FC-300 E4/C5

FC-300 external expression pedal4/external
footswitch5

FC-300 CTL6

FC-300 external footswitch6

FC-300 E5/C7

FC-300 external expression pedal5/external
footswitch7

FC-300 CTL8

FC-300 external footswitch8

CC (Control Change)

OFF, #1–#31, #64–#95

This sets the Control Change number to be
output.

* When the MONO/POLY setting is set to

POLY, messages are output only over the
basic channel; when this is set to MONO, the
messages are output over the six channels
starting from the basic channel.

TX PC STRING 1–6

This sets the Program Change messages for each string that are out-
put when the VG-99’s patches are switched.

BANK MSB

OFF, 1–127

This sets the Bank Select (MSB).

BANK LSB

OFF, 1–127

This sets the Bank Select (LSB).

Parameter/
Range

Explanation

PC (Program Change)

OFF, 1–128

This sets the Program Number.

Parameter/
Range

Explanation

HOLD CTL (Hold Control)

This setting determines the controller used for the HOLD function.

GK S1, S2

GK-3 DOWN/S1, UP/S2 switch

CTL1, 2

Control button1, 2

CTL3

Footswitch connected to the CTL3,4 jack

FC-300 CTL1,2

FC-300 control pedal1, 2

FC-300 CTL3–8

FC-300 external footswitch3–8

BEND THIN

OFF, ON

Setting this to ON thins out the Pitch Bend
messages and reduces the volume of MIDI
data.

BASIC CH (Basic Channel)

1–11

This sets the MIDI transmit channel used for
the GUITAR TO MIDI function.

PC MASK (Program Change Mask)

OFF, ON

When set to ON, the Bank Select messages
and Program Change messages used for the
GUITAR TO MIDI function are not trans-
mitted when patches are changed.