Sampling procedure, Screen (p. 112), Appear (p. 112) – Roland MC-909 User Manual

Page 112: Parameters

Advertising
background image

112

Sampling procedure

1.

Press [SAMPLING/RESAMPLING] to access the
Sampling Menu screen.

fig.5-01

The upper part of the screen will show the amount of free
memory. If the free memory reaches 0%, no further sampling is
possible.

2.

Press [F1 (Sampling)]–[F5 (Solo)] to select the
sampling mode. The sampling-standby screen will
appear.

(Example) Standby screen for Sampling

fig.5-02

3.

Make the settings for things such as the input source

of the sound to be sampled, and triggering.

Function buttons

Parameters

[F1 (Sampling)]

Sample a sound from an external input source.
* Operating the velocity pads or D Beam con-

trollers will not play the internal sound gen-
erator.

[F2 (Re-Sampling)] Resample the sound of the internal sound gen-

erator.
* The sound of the external input will not be

heard.

[F3 (Mix)]
(Mix sampling)

Sample the combined sounds of the internal
sound generator and an external input source.

[F4 (Auto Divide)]
(Auto divide sam-
pling)

Sample an extended source, and automatically
divide it into several samples at silent regions.
* Operating the velocity pads or D Beam con-

trollers will not play the internal sound gen-
erator.

[F5 (Solo)]
(Solo sampling)

While playing the internal sound generator as
usual, sample only the sound from the external
input.
* Effects cannot be applied to the external in-

put sound.

[F6 (Cancel)]

Return to the previous screen.

[F1 (Input Setting)]

Make settings for the external input (p. 34).

[F2 (Auto Trig)]
(Auto Trigger)

If this is on, sampling will begin automati-
cally when the input sound is detected.

[F3 (Trim Sw)]

If this is turned on, the Start point and End
point settings (p. 115) will be automatically
adjusted after sampling is performed, so
any silent portions at the beginning or end
of the sampled sound are excluded.

[F4 (BPM/Click)]

Set the tempo, and turn the metronome on/
off (p. 25).

Parameter

Range

Explanation

Input Select

LINE IN L/R,
LINE IN L,
DIGITAL(OPT),
DIGITAL(CO-AX),
MICROPHONE

Input source to be sampled

LINE IN L/R:

INPUT

jacks L/R (stereo)

LINE IN L:

INPUT jack L

(mono)

DIGITAL(OPT):

Digital

input (optical)

DIGITAL(CO-AX):

Digi-

tal input (coaxial)

MICROPHONE:

INPUT

jack L (mono, mic level)

* This cannot be set when

resampling.

Stereo
Switch

MONO, STEREO

Stereo/mono setting for
sampling

MONO:

The sound will

be sampled as one wave.
If the sound is stereo, the
left and right signals will
be mixed.

STEREO:

The sound

will be sampled as two
waves, L and R.

* Mono sampling uses

half as much memory
space.

Pre Sample
Time

0–1000 ms

The length of sound pre-
ceding the moment at
which sampling was man-
ually or automatically initi-
ated that will be captured
in the sample

This lets you prevent the
attack portion of the
sound from being omit-
ted from the sample.

Stop Trigger

MANUAL, BEAT,
TIME

How sampling will end

MANUAL:

Continue

sampling until you press
[F5 (STOP)].

BEAT:

Sample the spec-

ified number of beats at
the current tempo
(BPM).

TIME:

Sample the speci-

fied length of time.

MC-909_Ref_e.book 112 ページ 2005年3月1日 火曜日 午後3時29分

Advertising