4.8.2 Battery Replacement

The [

] illumination indication shows lithium battery deterioration, which is

used for memory backup. The battery has a lifetime of approximately 10 years under
normal operation.
When [

] is illuminated, contact Omega Engineering.

Replacing the lithium battery can be dangerous. Do not attempt to replace the
battery; never disassemble the recorder for replacing the battery.

4.8.3 Fuse Replacement

!

Replacing the fuse every two years is recommended as preventive maintenance.
Replacing procedure is as follows:

(1) Turn the power switch OFF.
(2) Take out the chart cassette; the fuse holder is found in the main unit.

Turn the fuse carrier counterclockwise to release it with the fuse.

(3) Change the fuse with a new one, and insert the carrier to the fuse holder turning it

clockwise for fixing.

Fuse Replacement

• To protect against personal injury, turn the power switch OFF and disconnect

the recorder from the main power line before replacing the fuse.

• To protect against an accident such as a fire, use only the specified fuse

Fuse part number:

A1360EF

Original manufacturer:

Shelter

Littel

Original manufacturer’s product code: FST0034.524

313.500

Ratings:

250V AC T 0.5 A

250VACT 0.5 A

Recorders with a gray power switch

Fuse part number:

A1512EF

Original manufactturer:

wickmann-Werke GmbH

Original manufacturers product code:

No.19195

Ratings:

250V AC T0.8A

Recorders with a white power switch

4.8.4 Cleaning the Carriage Shafts

WARNING

WARNING