FREE Dive Mode has its own set of Alarms which emit 3 short beeps either 1 or 3

times which cannot be acknowledged or set Off.

A red LED Warning Light, located on the left side of the housing, is synchronized

with the Audible Alarm. It will flash as the Audible Alarm sounds. It will turn Off

when the Alarm is acknowledged or the situation is corrected. The Audible and

LED will not be active if the Alarm is Set OFF (a group A setting).

Situations that will activate the NORM/GAUG 10 second Alarm include -

 Descent deeper than the Max Depth Set Point selected.

 Dive Time Remaining at the Set Point selected.

 Elapsed Dive Time at the Set Point selected.

 High PO2 at the Set Point selected.

 High O2 of 300 OTU (single or daily exposure).

 Tissue Loading Bar Graph at the segment Set Point selected.

 NORM/GAUG Ascent Rate exceeds 60 FPM (18 MPM) when deeper than

60 FT (18 M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.

 Entry into Decompression Mode (Deco).

 Conditional Violation (above a required Deco Stop Depth for less than 5

minutes).

 Delayed Violation (above a required Deco Stop Depth for more than 5

minutes).

 Delayed Violation (a Deco Stop Depth greater than 60 FT/18 M is required).

 Delayed Violation (Maximum Operating Depth of 330 FT/100 M is

exceeded).

 Watch Daily Alarm reaches time set (disabled during Dive Modes).

 Watch Mode Countdown Timer reaches 0:00.