 Pressing and releasing the A button momentarily (< 2 seconds) will advance

to SAT MODE.

 Depressing and holding the M button for 2 seconds will revert to the NORM

(or GAUG) SURF MAIN screen.

 If no button is pressed during a 2 minute period, operation will revert to the

NORM (or GAUG) SURF MAIN screen.

 Pressing the L button will activate the Backlight.

DESAT MODE

The Time to Desaturate counter provides calculated time for Tissue Desaturation at

sea level taking into consideration the Conservation Factor setting. It begins

counting down 10 minutes after surfacing from a NORM (or FREE) dive, counting

down from 23:50 max to 0:00 (hr:min).

When the Countdown reaches 0:00, which will generally occur prior to the FLY

countdown reaching 0:00, the SAT screen remains in the sequence of accessible

screens displaying 0:00 until the FLY counter shuts the Dive Computer operations

Off 24 hours after a last dive.

> The SAT screen is not displayed after a Violation Dive.

> DESAT Times greater than 24 hours will be displayed as 23: - -

> In the event that DESAT Time still remains at the end of the 24 hours

countdown, the added time will be zeroed.

> Ten minutes after surfacing from a dive, operation reverts to the Watch Mode

Time screen at which time the DESAT Countdown continues in the

background. Access to the SAT screen can then be gained by first accessing

the NORM SURF MAIN screen.