Oceanic Watch / Dive Computer GEO User Manual

Page 96

Advertising
background image

96

POST DIVE SURFACE MODE

When you ascend to 2 FT (0.6 M), the GEO will enter Surface

Mode and begin counting your Surface Interval.

TRANSITION PERIOD

If you descend during the first 10 minutes after surfacing

(referred to as the Transition Period), time underwater will be

considered a continuation of that dive. The time at the surface

(if less than 10 minutes) will not be added as Dive Time.

Transition Period information on the surface includes (Fig. 90):

> TLBG, representing Nitrogen loading.

> Graphic NORM alternating with the graphics SEA (or EL2

through EL13) and WET (if wet). If a Low Battery

condition occurs during a dive, the message CHNG >

BATT will scroll upon surfacing.

> Battery icon if a Low Battery Warning Condition exists,

flashing if Too Low.

> Surface Interval Time (hr:min) with SURF and TIME icons.

> Dive Number with DIVE icon.

> Nx icon, if FO2 is set for Nitrox.

During the Transition Period, Alternate displays and the Log for

that dive can be accessed. Other modes (e.g., Plan, Fly, Sat,

Hist, Set) will be accessible after 10 minutes on the surface.

Fig. 90 - TRANSITION

PERIOD

Advertising