Category

Controller errors Optional Software ROM

Check Error

An error was detected by optional
software ROM check.

Check the optional software ROM
board for proper connection or
replace it.

PC display status message

Trouble or status

Remedy

Optional RAM Check
Error

FAN Motor Error

Fuser Error

Thermistor Short Check
Error

A fault occured in the fusing unit.
(Thermistor short check error)

See 6.5.2-

4

.

SSIO Interface Error

Power supply board SSIO I/F error Replace the power supply board or

the Main Control PCB.

A fault occured in the fusing unit.
(Timeout error, etc.)

See 6.5.2-

4

.

Thermistor Open Check
Error

A fault occured in the fusing unit.
(Thermistor open check error)

See 6.5.2-

4

.

A fault occured in the fan motor.

– Check the fan motor for proper

connection and for any presence
of foreign matter in the fan.
(See 6.5.2-

5

.)

– Replace the fan motor or the

Main Control PCB.

An error was detected by optional
RAM check.

– Check the optional RAM board

for proper connection.

– Check the mounting position of

short plugs and additional RAM
chips. (See 7.4.)

– Replace the optional RAM board.

Table 6-1 (Cont'd)