Fusing unit error (ERROR 71) (ERROR 72) (ERROR 73)

• Turn the power off, then back on.

• Does the fusing unit error occur immediately?

• Yes

Is the thermistor open or shorted?
Measure the resistance between
thermistor contacts (about 220k

at

room temperature) (see Fig. 6-2 or
see 7.3).

• Yes Replace the fusing unit.

• No

Do the thermistor contacts touch the contact assembly properly when the

fusing unit is mounted in the printer (see Fig. 6-4 contact

F

)?

• No

Adjust the contact.

• Yes

Replace the Main Control PCB or power supply board.

• No

Does the fusing unit error occur about 60 seconds after the power is turned on?

• No

Check the thermistor for poor contact or replace the Main Control PCB.

• Yes

Turn the power off, then back on.

• Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)?

• Yes

Check thermistor contacts or replace the Main Control PCB or the fuser unit.

• No

Is the heater or the thermostat open?
Measure the resistance between the heater contacts (normal resistance: about 0

)

(see Fig. 6-2 or see 7.3).

• Yes

Replace the fusing unit.

• No

Is the AC voltage being supplied to the contacts for the heater of the contact assembly?
(Refer Fig. 6-2)

• No

Replace the Main Control PCB or the power supply board.

• Yes

Check the heat contact of the fusing unit and the contact assembly for poor contact
(see Fig. 6-4 contact

G

).

Themistor contacts

Heater contacts

Figure 6-2