Oki 6E User Manual

Page 191

Advertising
background image

C - 5

1.3

Engine Maintenance Mode

(1) The engine maintenance mode is activated when the power is turned ON while keeping the

Form Feed key and Enter key pressed down.

(2) This mode adopts the menu for function selection.

(3) The method for exit from this mode depends on the setting.

(4) The engine maintenance mode provides the following functions:

(a) Head type setting

Set the type of the LED head. (300-1W or 300-2W or 600-4W)

(b) Head drive time setting

Sets the drive time of the LED head.

(c) Head width setting

Sets the width of the LED head. (39 chips or 40 chips)

(d) Head type

Only for the 600dpi head, the adjustment method for the adjustment head is set.

(e) Strobe time

Only for the OKIPAGE 6ex, 600dpi head, the percentage of the strobe time for
600*1200dpi to the strobe time of 600*600dpi is set.

(f)

Transfer current setting

Set transfer current value according to humidity and medium status for optimum
printing result.

(g) Printing start position setting

Sets the printing start position. Do not change the default setting.

(h) Drum count total display

Displays on the LCD the total number of drum revolution of the unit, counted at the
engine block.

(i)

Drum count display

Displays on the LCD the total number of EP drum revolutions counted at the engine
block.