3 - 26

3.3.20 Main Control PCB

Note: When replacing the Main Control PCB, the contents of the EEPROM shall be copied to the

new PCB. This process requires a maintenance utility. (See 4.3.1

4

and 4.3.2

4

for

details.)

The Main Control PCB is different for each model.

OKIPAGE 6e

: L5C or L5D

OKIPAGE 6ex

: L6A

(1) Remove the upper cover (see 3.3.1).

(2) Remove the lower base unit (see 3.3.8).

(3) Remove two screws

1

.

(4) Move the Main Control PCB

2

in the direction of arrow

A

to disconnect it from the power

supply board

3

.

(5) Remove the Main Control PCB

2

together with the PCB guide plate

4

(disconnect the fan

motor connector

5

from the Main Control PCB).

(6) Remove three screws

6

and remove the PCB guide plate

4

from the Main Control PCB

2

.

Do not bend or lose ground plate